AIA Logo Online
Continuing
Education




 

Interior Acoustical Panels

Correctional Ceiling Panels Select TAG to import BIM product files.

Mayo Correctional - Mayo FL
Designed to meet the specific security and acoustical requirements in confinement areas, the Tectum Direct Attachment Ceiling/Wall System has been successfully used in hundreds of correctional facilities across the country. The system is ideal for large, open areas such as dormitories and dining halls, as well as corridors where one long, steel-backed panel can span the corridor width. To install, simply attach the panels in an Ashlar pattern directly to the ceiling, furring, or drywall suspension grid using tamper-resistant screws.
Interior Acoustical Ceiling Panel Correctional - TECTUM

NRC/Mountings - Noise Reduction
Up to 1.00 NRC can be achieved depending on mounting style. Furring strips installed horizontally (when using
vertical panels) are recommended and should be a maximum of 24" o.c. when using 1"-thick panels.

Installation Instructions

  • I-16 Tectum Correctional Interior Panel Installation Instructions (Coming Soon)

Drawings

ASTM E-84 - Flame Spread/Smoke Developed

Tectum Interior Ceiling Panels - 0 Flame Spread, 0 Smoke Developed

Sizes & Finishes

Tectum Security Ceiling Panels are available in a 1" thickness with all four sides of the panel beveled, or a 1½" thickness with T&G detail on all four sides. Both thicknesses are available in 24" widths and lengths up to 96". Tectum Security Ceiling Panels are available in natural, painted white or custom colors, and can easily be field painted up to six times without losing their acoustical efficiency.

Weights

  • 1" - 3.65 lbs./square foot

  • 1½" - 4.55 lbs./square foot

  • 2" - 5.50 lbs./square foot

R-Value

  • 1.75 per inch of thicknes
Light Reflectance

Tolerances

Tectum ceiling and wall panel measurements are plus or minus
1/8 - 1/4". Thicknesses are nominal. Panels that are to be butted must be beveled and will require field fitting or molding can be used to cover edges.

Limitations

Tectum Acoustical Panels can be used over swimming pools and in open construction such as breezeways and open garages. They should not be installed where they will come in direct contact with water or condensation. Reveal edge panels (Tonico) should not be used for this purpose.

1" panels should not be used where the relative humidity will exceed 85%. Panels 1½" or thicker are not restricted by humidity conditions.

In all cases, the plenum must provide cross-ventilation to prevent condensation.

Sign Up for Email Updates

Tectum Manufacturing Facility, PO Box 3002, Newark, OH 43058 • 888-977-9691 • 740-345-9691 Copyright© 2017

Tectum, Acousti-Tough and Fabri-Tough are registered trademarks of Armstrong World Industries.