V-Line Interior Panels offer extra value and installation ease plus all the features you expect from Tectum Acoustical Products. V-Line Interior Panels attach directly for a continuous installation with no visible seam. The “V” groove is ¼” deep to match the beveled edges, and the design divides the 2’ or 4’ wide panel into equal segments approximately 8” wide.
V-Line Interior Wall Panels - TECTUM

NRC/Mountings - Noise Reduction

Up to 1.00 NRC can be achieved depending on mounting style. Furring strips installed horizontally (when using
vertical panels) are recommended and should be a maximum of 24" o.c. when using 1"-thick panels.

Installation Instructions

Drawings

ASTM E-84 - Flame Spread/Smoke Developed

Tectum Interior Wall Panels - 0 Flame Spread, 0 Smoke Developed

SIZES & FINISHES

Lengths from 2’ to 12’ with widths of 23¾" and 47¾" are available in 1”, 1½” and 2” thicknesses. Tectum V-Line Interior Panels are available in natural, painted white or custom colors, and can easily be field painted up to six times without losing their acoustical efficiency.

Weights

  • 1" - 1.65 lbs./square foot

  • 1½" - 2.55 lbs./square foot

  • 2" - 3.50 lbs./square foot

R-Value

  • 1.75 per inch of thickness

Tolerances

Tectum ceiling and wall panel measurements are plus or minus
1/8 - 1/4". Thicknesses are nominal. Panels that are to be butted must be beveled and will require field fitting or molding can be used to cover edges.

Limitations

Tectum Acoustical Panels can be used over swimming pools and in open construction such as breezeways and open garages. They should not be installed where they will come in direct contact with water or condensation. Reveal edge panels (Tonico) should not be used for this purpose.

1" panels should not be used where the relative humidity will exceed 85%. Panels 1½" or thicker are not restricted by humidity conditions.

In all cases, the plenum must provide cross-ventilation to prevent condensation.